首页产品总目录 液冷机柜与服务器/通用液冷机柜与服务器

液冷CDU_Liquid-Cooled_CDU

OT-00256 · 液冷CDU_Li · AI数据中心 / 液冷机柜与服务器/通用液冷机柜与服务器

数据质量 中 AI 数据中心与算力基础设施消费电子与边缘 AI 终端
液冷CDU_Liquid-Cooled_CDU

厂商规格表(原文)

直接取自厂商产品规格书,未经改写,可作为选型依据引用。

关键词Liquid-Cooled CDU
分类Liquid cooled products
应用领域High-Performance Computing (HPC), Data Centers

产品简介

The cabinet-type CDU primarily consists of a cabinet, water pump, plate heat exchanger, valves, expansion tank, and piping. Heat exchange is achieved through the plate heat exchanger: the cooled fluid is delivered to the heat source to absorb heat, after which the heated fluid returns to the plate heat exchanger for further heat exchange, thus completing a continuous heat-transfer cycle.

技术特点与优势

The cabinet-type CDU primarily consists of a cabinet, water pump, plate heat exchanger, valves, expansion tank, and piping. Heat exchange is achieved through the plate heat exchanger: the cooled fluid is delivered to the heat source to absorb heat, after which the heated fluid returns to the plate heat exchanger for further heat exchange, thus completing a continuous heat-transfer cycle. Liquid-cooled CDUs absorb, transfer, and dissipate the heat generated by electronic equipment during operation through liquid circulation. Liquid-cooled CDUs are highly adaptable, allowing the cooling mode to be adjusted according to varying environmental requirements, and can operate reliably in extreme conditions such as high temperatures and high humidity. It can provide a stable thermal environment, ensuring that equipment operates within a consistent temperature range and effectively reducing the failure rate. Under high-load operation, energy consumption can be reduced more effectively, leading to lower energy costs and providing strong support for sustainable development. It controls key parameters such as coolant flow rate and temperature, and dynamically allocates coolant resources in accordance with the system’s real-time demands, ensuring that the cooling process is always optimized. Cooling medium is delivered via pipelines and pumps to heat-generating IT equipment such as servers,

认证与资质状态(引擎自动标注,2026-09-15 21:56):企业资质 ISO 9001:待核实;企业资质 ISO 14001:待核实;企业资质 ISO 45001:待核实;企业资质 IATF 16949:待核实;企业资质 QC:待核实;产品认证 UL:待核实;产品认证 CE:待核实;产品认证 UKCA:待核实;产品认证 ETL:待核实;产品认证 CSA:待核实;产品认证 CCC:待核实;产品认证 CB:待核实;产品认证 TUV:待核实;产品认证 VDE:待核实;产品认证 FCC:待核实;产品认证 RoHS:待核实;产品认证 REACH:待核实。供应商提交凭证:认证提交通道(证书扫描件 + 证书编号 + 发证机构三必填);凭证审核通过前一律「待核实」。